Temperature Calibrators AMETEK CTC Series

The CTC Series Portable Temperature Calibrator is a fast, time-saving, and highly reliable dry block temperature calibrator designed for on-site use. High accuracy. The large color display is easy to read and provides icons and information on calibrator status and calibration in progress.

Two temperature calibrator models (A and C) are available for each type, from the basic unit to a complete model including signal inputs and external reference sensor.

Popular functions, such as the automatic switch test and automatic step-by-step calibration with Auto stepping, are available with special one-key, one-function buttons.

The CTC series calibrator features dual-zone active temperature control, which provides excellent temperature homogeneity in the thermal block and insert.

Automatic calibration function (auto-step) in 20 temperature points, locally controlled

Speed, portability, cleanliness, and a wide temperature range are all superior to liquid bath systems.

ADVANTAGES:

  • • Temperature range from -25 to 1205°C (-13 to 2201°F) with 5 models
    • Accuracy at ± 0.2°C and stability at ± 0.04°C
    • Long sensor calibration with CTC-652s, 190 mm immersion depth
    • Lightweight and easy to carry
    • Sets with multiple holes and/or metal inserts
    • External reference sensor input on all C models
    • MVI circuit (Main power Variance Immunity)ensures stability despite supply voltage variations
    • Rugged, lightweight, portable temperature calibrator.

Basic technical characteristics of the CTC series Calibrators
Temperature range from-25 to 1205°C (-13 to 2201°F)with 5 models available
Calibrator Accuracy Over the Full Range, with External Reference Sensor ± 0.2°C/ /±0.36°F over 12 months of continuous operation
Stability ± 0.04°C; ±0.07°F
Radial homogeneity 0.03 °C
Axial homogeneity 0.01 °C
Available variants With dry block
Resolution at all temperatures-user selectable 1°; 0.1°; 0.01°.
STS sensor temperature measurement block, tested sensors (built-in). Accuracy (over 12 months): +/- 0.003% rdg.
STS 102A Reference Sensor Accuracy: Stability +/- 0.014°Cfor 12 months

Repeatability 0.002 °C

Hysteresis 0.01°C

Sensor immersion depth in insert 120mm
Integrated block measurement inputs

 

External Reference Sensor type STS and test switch
Display Full color
Keyboard Integrated, intuitive, temperature setting and calibrator parameterization, work-list planning
Power consumption: 130 – 1150 VA
Calibrator table 5.5 – 6.1 kg

 

AVAILABLE MODELS MEASUREMENT BLOCK TEMPERATURE RANGE
CTC-155

 

Dry block -25…+155 °C
CTC-350 Dry block +28…+350 °C
CTC-652 Dry block +28…+650 °C
CTC-660 Dry block +28…+660 °C
CTC-1205 Dry block +100…+1205 °C