Coriolis mass flowmeter CoriolisMaster FCD450 ABB
Built on reliable CoriolisMaster electronics, the low-flow Coriolis meter provides maximum precision measurements even at low flow rates of liquids, gases, and steam. Small meter sizes available: DN08 (5/16 in.) and DN10 (3/8 in.).
With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.
KEY FEATURES:
- Up to five modular I/Os
- SmartSensor
- SensorApplicationMemory
- ABB common look and feel
- VeriMass on-board verification and diagnostics
- Designed for 70 °C (158 °F) ambient temperature and high vibrations
- Enhanced Coriolis control (ECC) option for advanced measurement for multiphase conditions and other challenging fluids
- Low pressure drop
- Self-draining
- Global approvals for explosion protection
The FCB450 adds:
- DensiMass software for direct concentration measurement
- FillMass software for filling application control
Technical specifications Coriolis mass flowmeter CoriolisMaster FCD450 ABB:
Nominal sizes / measuring ranges
|
– DN 8 (5/16 in.) / 0 to 600 kg/h (1,320 lb/h)
– DN 10 (3/8 in.) / 0 to 2,500 kg/h (5,514 lb/h) |
Ex approvals
|
ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
NEPSI Zone 0/1/2 Various other approvals |
Wetted materials | 1.4404 / 1.4435 (316L) or Hasteloy C |
Accuracy for liquids
|
FCD450
Mass: 0.1 % o. r., volume: 0.15 % o. r. Density: 10 g/l or 5 g/l or 1 g/l |
Measuring medium temperature
|
FCB450
– -50 to 220 °C (-58 to 428 °F) |
Outputs Coriolis mass flowmeter
|
5 modular I/Os
HART 7.1 PROFIBUS DP Modbus Ethernet
|
Power supply
|
11 to 30 V DC, 110/230 V AC
Power over Ethernet |