Coriolis mass flowmeter CoriolisMaster FCH430 and FCH450 ABB
With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.
KEY FEATURES:
- Designed for hygienic applications
- Up to five modular I/Os
- SmartSensor
- SensorApplicationMemory
- ABB common look and feel
- VeriMass on-board verification and diagnostics
- Designed for 70 °C (158 °F) ambient temperature and high vibrations
- Enhanced Coriolis control (ECC) option for advanced measurement for multiphase conditions and other challenging fluids
- Lower pressure drop
- Self-draining
- Global approvals for explosion protection
The FCH450 adds:
- DensiMass software for direct concentration measurement
- FillMass software for filling application control
Coriolis mass flowmeter CoriolisMaster FCH430 and FCH450:
Technical specifications: | |
Nominal sizes / measuring ranges
|
DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h) DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h) DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) |
Ex approvals
|
ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 NEPSI Zone 0/1/2 Various other approvals |
Wetted materials | 1.4404 / 1.4435 (316L) |
Accuracy for liquids
|
FCH430 Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r. Density: 10 g/l FCH450 Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r. Density: 2 g/l or 1 g/l or |
Measuring medium temperature
|
FCH430 -50 to 160 °C (-58 to 320 °F) FCH450 -50 to 205 °C (-58 to 400 °F) |
Outputs CoriolisMaster FCH430
|
5 modular I/Os, HART 7.1, PROFIBUS DP, Modbus, Ethernet. |
Power supply
|
11 to 30 V DC, 110/230 V AC
Power over Ethernet |