Condumax Dew-Point Analyzer CD603 Michell
Automatic online hydrocarbon and water dew-point analyzer
The Michell CD603 – Condumax Dew-Point Analyzer is specifically designed for continuous and automatic measurement of the hydrocarbon and water dew points in processed natural gas. Built on over 50 years of expertise in delivering analyzers to the global oil, gas, and petrochemical industries, it offers proven reliability and performance.
The system features a combined hydrocarbon and water dew-point sensor cell along with control electronics, all housed in an Exd-rated enclosure. Additionally, an optional gas handling panel is available to condition the sample gas before it enters the analyzer. The Michell CD603 – Condumax Dew-Point Analyzer is intended for installation near the process sample point for optimal functionality. It is certified for safety and compliance under ATEX, UKEX, and IECEx standards.
Suitable Applications:
- Natural gas processing
- Gas quality measurements at custody transfer
- Transmission pipeline monitoring
- Confirmation and control of fuel gas ‘superheat’ to turbine power plant
Key features:
- Fundamental cooled-/chilled-mirror dew-point measurement principle
- Fully automatic identification of both water and hydrocarbon dew point
- Greater than 65 ˚C (117 °F) measurement depression range
- ±0.5 ˚C (±0.9 °F) hydrocarbon dew-point accuracy
- IECEx, ATEX, cQPSus and UKEX certifications
- 100 barg (1450 psig) operating pressure rating
- 3 x 4…20 mA user-configurable outputs
- 1 x system alarm, 3 x process alarms, selectable for all measurement parameters
- Modbus RTU or TCP/IP interface
- Suitable for use with natural gas containing up to 20 % hydrogen with
no further modification required.
TECHNICAL SPECIFICATIONS:
Hydrocarbon & Water Dew-Point Measurement
|
Measuring Technique: Chilled Mirror
Sensor Cooling: Automated cooling rate control Maximum Range Maximum cooling = >65 °C (117 °F) ΔT from analyzer operating temperature HCdp Accuracy ± 0.5 °C (± 0.9 °F) Wdp Accuracy ± 0.8 °C (± 1.4 °F) Resolution 0.1 °C (0.1 °F) Sample Flow Nominally 0.1 Nl/min (0.0035 scfm) |
Pressure Measurements HCDP & WDP
|
Units MPa, barg, psig
Resolution 0.1 MPa, 0.1 barg, 1 psig Accuracy ± 0.25 barg (3.6 psig) |
Interfaces
|
Analog Outputs
Three 4…20 mA linear (non-isolated) outputs, user configurable for any combination of dew-point or pressure parameters. Max shunt resistance 400 ohms. Digital Outputs 1 x system alarm, 3 x process alarms, selectable for all warnings and measurement parameters, all voltfree changeover. Modbus RS485 or TCP/IP |
Power Supply
|
AC Version (Ex1) 85…264 V AC, 50/60 Hz, 18 W 36 VA
DC Version (Ex2) 18…36 V DC, 18 W |